•TS345/TS345P Square Termination Cap
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks.
3 in. (76 mm)
Maximum
top of chase to top of
chimney section
Chase
Termination cap pipe and chimney section must overlap
Figure 9.7 Installing a TS345/TS345P Square Termination Cap
•TCT375 Terra Cotta Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks.
Termination Cap
The last section of pipe must stop between 2 in. (51 mm) above top of chase and 7 in. (178 mm) below top of chase
2 in. (51 mm)
7 in. (178 mm)
Chase
Chimney
Pipe
Termination cap pipe and chimney section must overlap
Figure 9.8 Installing a TCT375 Terra Cotta Cap
34 | Heatilator • SC60 • 32838 Rev X • 10/08 |