E. Optional Wall Switch / Thermostat Wiring Connections instructions

The optional wall switch and thermostat wiring is low voltage and must be separated from power wiring. Do not connect the switches or thermostat to house power.

To control the fireplace with a single switch:

(flames/ember bed and heater/front embers all on or all off)

Switch between terminal 1 and 2

Jumper wire between terminal 2 and 3

Jumper wire between terminal 4 and 5

To control flames/ember bed with one switch and heater/front embers with another switch:

Switch 1 - turns flames/ember bed ON/OFF

Switch 2 - turns heater/front embers ON/OFF

Switch 1 between terminal 1 and 2

Switch 2 between terminal 1 and 3

Jumper wire between terminal 4 and 5

To control flames/ember bed with a switch, and control the heater with a thermostat:

Switch 1 - turns flames/ember bed ON/OFF

Switch 2 - turns front embers ON/OFF indicating the heater/fan is being controlled by the thermostat (UL requirement)

Thermostat turns heater/fan ON/OFF as room temperature requires it

Switch 1 between terminal 1 and 2

Switch 2 between terminal 1 and 3

Thermostat between terminal 4 and 5