Hearth and Home Technologies WSK-MLT Operating Instructions, Wall Switch Button Operation

Models: WSK-MLT

1 7
Download 7 pages 16.92 Kb
Page 6
Image 6
2.0 Operating Instructions

2.0 Operating Instructions

For units WITH factory installed rocker switch.

The ON/OFF rocker switch on the fireplace (located near the gas valve) must be in the “OFF” position for use with the WSK-MLT system. The ON/OFF rocker switch will NOT function with this device on Intellifire (IPI) models except during a power outage.

For units WITHOUT factory installed rocker switch.

The ON/OFF rocker switch now installed on the fireplace must be in the OFF position for use with the IPI or stand- ing pilot system. The ON/OFF rocker switch will only be used to control the fireplace in a no-power condition. For standing pilot systems use the rocker switch to turn the fireplace on and off. When power is restored switch the rocker switch to OFF. For IPI system refer to “Operation Under Battery Power” for instructions.

After all connections are made and the control box is grounded, plug power cord into the fireplace junction box. The wall switch will be functional at this time.

NOTE: The temperature displayed by the wall switch may take up to 30 minutes to stabilize on initial power-up.

NOTE: Check control box and assure switch is in the “OFF” position. This switch is only used on Intellifire (IPI) control systems under battery operation.

Figure 7.

2.1 Setting Flame Height/manifold pressure

(To be done by a qualified service technician). Upon initial power-up of this device, valve pressure must be set for flame adjustment.

Loosen output pressure tap on valve and connect with pressure manometer.

Press flame button once (Fig. 7); fireplace will light with flames on high.

Turn solenoid clockwise to increase pressure, counter- clockwise to decrease pressure until manifold pressure on high is 3.5” water column for natural gas (NG), 10.0” water column for propane (LP).

Once pressure is achieved spin jam-nut on solenoid stem tight against regulator face to prevent rotation. Do not overtighten.

Press flame button twice to turn fireplace off.

Remove manometer tube and tighten or close pressure tap. Use a soap solution to carefully check the pressure tap for leaks.

2.2 Wall Switch Button Operation

(Refer to Figure 7) For units WITH factory installed rocker switch.Flame Button

Button Press: Unit On / Flames High, Turns on auxiliary power

Button Press: Flames Low

Button Press: Unit Off / Flames Off, Turns off auxiliary power

For units WITHOUT factory installed rocker switch. Fan / Blower Button

Button Press: Fan High (“3”)

Button Press: Fan Medium (“2”)

Button Press: Fan Low (“1”)

Button Press: Fan Off

2.1 Setting Flame Height/manifold pressure Temperature Button

Button Press will toggle between Automatic and Manual Operation

Press and Hold the button for 3 seconds to toggle between Fahrenheit and Centigrade Temperature Display.

Automatic Operation: Controller will monitor temperature and control unit according to the set point.

Manual Operation: Controller will not automatically change settings.

SET Set Temperature Button

Button Press: Displays Set Point

Use Up and Down Arrows to Adjust Set Point

Press Set Button to Store New Set Point

Temperature Set Point can be adjusted between the ranges of: 45-900Fahrenheit or 7-320Centigrade

NOTE: The controller will turn off the fireplace at 20 F over set point and turn it back on at 20 F below set point.

<>Up and Down Arrows

Push to adjust set point temperature under automatic control.

AUX Auxiliary Button

Button Press: Turns on auxiliary power

Button Press: Turns off auxiliary power

Can be operated independently of all functions.

6

Page 6
Image 6
Hearth and Home Technologies WSK-MLT Operating Instructions, Setting Flame Height/manifold pressure, Refer to Flame Button