Heat & Glo LifeStyle 36DV owner manual Listing and Code Approvals

Models: 36DV

1 58
Download 58 pages 12.02 Kb
Page 4
Image 4

1 Listing and Code Approvals

A. Appliance Certification

MODELS: Escape-36DV, Escape-36DVLP

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Direct Vent Gas Appliance Heater

STANDARD: ANSI Z21.88-2000CSA2.33-M98 • UL307B

This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. BTU Specifications

Models

 

Maximum

Minimum

Orifice

 

Input

Input

Size

(U.S. or Canada)

BTU/h

BTU/h

(DMS)

 

 

 

 

 

 

 

 

US

41,000

27,000

30

Escape-36DV

 

(0-2000 FT)

 

 

 

 

 

CANADA

36,900

24,300

31

 

 

 

 

(2000-4500 FT)

 

 

 

 

 

 

 

 

US

40,000

31,000

49

Escape-36DVLP

 

(0-2000 FT)

 

 

 

 

 

CANADA

36,000

27,900

50

 

 

 

 

(2000-4500 FT)

Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

Heat & Glo Quality Systems registered by SGS ICS

C. High Altitude Installations

U.L. Listed gas appliances are tested and approved with- out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A., or 10% for el- evations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

D. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750ºC, shall be considered non-combustible materials.

E. Combustible Materials Specification

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ig- nite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.

4

Heat & Glo • Escape-36DV2012-900 • Rev. AA • 04/08

Page 4
Image 4
Heat & Glo LifeStyle 36DV owner manual Listing and Code Approvals