For Intermittent Pilot Ignition (IPI) Wiring

3 Volt Transformer

This appliance comes with a 3 volt transformer found in the manual bag. Plug the transformer leads to the green con- trol module (see Figure 12). Then plug the transformer into the side outlet on the junction box.

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the junction box included in the manual bag assembly. Maintain correct polarity when wiring the junction box.

The junction box is installed by sliding one tab of the box through the slot on the lower right side of the outer wrap and driving a screw through the other tab into the pilot hole on the outer wrap.

Operation using Battery Power

This fireplace has an optional battery operation. The sys- tem is fully functional with the use of two “D” size batteries without ordinary 110-120 VAC power.

Wiring to the battery pack should be left disconnected in order to conserve battery life. In the case of a loss of power, simply connect red and black wire leads to activate battery power (connect red to red, black to black). The fireplace can be used as necessary. Once power (110 VAC) is re- stored, disconnect red and black wire leads to extend bat- tery life.

Optional Accessories

Optional fan and remote control kits require that 110-120 VAC be wired to the fireplace junction box.

Wall Switch

Position the switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less of 16 A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtails.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA- TION. VERIFY PROPER OPERATION AFTER SERVICING.

TRANSFORMER OUTLET

TRANSFORMER

3V

 

 

 

 

 

 

 

 

 

SPARK TO

 

 

 

 

120 VAC

 

PILOT IGNITOR

 

 

 

 

 

 

JUNCTION BOX

 

IGNITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3V

PLUG-IN

 

3V TRANSFORMER

 

LOW VOLTAGE

FLAME SPARKER /

SEE NOTE 1

SENSOR

 

IGNITION

 

MODULE

 

(3V)

 

 

OPTIONAL

REM FAN

BLACK

ORANGE (IGNITOR)

WHITE (SENSOR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT ASSEMBLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND VALVE ASSEMBLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUST BE GROUNDED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIREPLACE

(COMMON GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHASSIS

WITH FIREPLACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHASSIS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BATTERY

 

BACK-UP

ON/OFF

 

WALL SWITCH

 

VALVE

LOW VOLTAGE

 

SEE NOTE 1

 

REMOTE

GROUND

CONTROL

NEUTRAL

HOT

 

 

E

 

 

 

OT

OPTIONAL

 

M

 

 

RE

 

 

BATTERY

 

 

 

 

 

 

 

 

BACK-UP

ORANGE

R

 

EMO

 

TE

RED

ON/OFF

 

SWITCH

 

 

BROWN

BROWN

GREEN

HIGH TEMP

LIMIT SWITCH

u

NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up.

Figure 12. Intermittent Ignition (IPI) Wiring Diagram