1.0 INTRODUCTION
The information in this manual pertains to Models CFL- 18
Gas Log Sets are Decorative Gas Appliances for Instal- lation in a
WARNING: This log set must NOT be installed in an unvented appliance.
This log set is to be installed only in a
WARNING: OPEN THE CHIMNEY DAMPER TO ITS FULLY OPEN POSITION WHEN BURNING THIS GAS LOG SET.
WARNING: LOGS MUST NEVER BE BURNED WITHOUT THE FLUE DAMPER IN THE FULL OPEN POSITION. FAILURE TO DO SO IS DANGEROUS TO YOUR HEALTH AND VOIDS ALL WARRANTIES.
WARNING: ALL GAS APPLIANCES PRODUCE SOME CARBON MONOXIDE WHEN OPERATED. CARBON MONOXIDE IS A COLORLESS, ODOR- LESS, POISONOUS GAS. ADEQUATE PROVISIONS MUST BE MADE TO PROVIDE COMBUSTION AIR FOR THIS GAS LOG SET. IF OUTSIDE AIR IS NOT INCLUDED IN THE FIREPLACE, IT MAY BE NEC- ESSARY THAT AN ADDITIONAL COMBUSTION AIR SOURCE BE PROVIDED.
CAUTION: CHECK THE CONSTRUCTION OF THE FIREPLACE BEFORE INSTALLING THE GAS LOG SET. THE AREA OF THE FLUE SHOULD NOT BE LESS THAN 1/11 THE AREA OF THE FIREPLACE OPENING
CAUTION: To minimize the possibility of spillage and to maximize proper draft, position the log set as close to the back of the fireplace as possible. The ST-
The installation, including provisions for combustion and ventilation air, must conform with the National Fuel Gas Code ANSI Z223.1 (in the United States), the CAN/ CGA
These models can be installed in a bedroom (in the United States) which has a total volume of unconfined space appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA 54- (current edition). The Uniform Mechanical Code (cur- rent edition), and Local Building Officials for the options allowed in obtaining an effective bedroom volume of un- confined space.
Always keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.
WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. SOLID FUELS SHALL NOT BE BURNED IN A FIREPLACE WHERE A DECORATIVE APPLIANCE IS INSTALLED.
2.0 ASSEMBLY
CAUTION: WHEN INSTALLING THIS LOG SET IN A FACTORY BUILT FIREPLACE, BE CERTAIN TO CONSULT THE FIREPLACE INSTALLATION MANUAL. ALL KNOCKOUTS IN THE FIREPLACE THROUGH WHICH THE GAS SUPPLY LINE IS RUN MUST BE RESEALED WITH INSULATION AFTER THE GAS LINE IS IN PLACE.
These models contain complete
assembly to the rear of the fireplace. The
A.Run proper size gas line into fireplace. A 1/2 inch (13mm) gas line, with a 3/8 inch (10mm) reduction for