![LIGHTING INSTRUCTIONS](/images/new-backgrounds/52213/5221337x1.webp)
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS
1."STOP!" Readthesafetyinformationonprevious page.
2.Open the control access cover (logs #3 and 4 in CFL models) or (logs #4 and 5 in
3.Turn the valve control knob to the "OFF" position. To do this, you must turn the knob
clockwise to the "Pilot" position, and then press in and continue turning
clockwise to the "OFF" position.
GAS CONTROL VALVE
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
4.WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow "B" in the safety information previous page. If you don't smell gas, go to the next step.
5.The pilot should not require accessing for lighting purposes. The pilot is located at the end of the burner.
THERMOPILE | PILOT BURNER |
6.To put the control in the "Pilot" position, turn the
control knob to the "Pilot" position.
7.To light the pilot depress the control knob and then depress the red piezo button until it makes a clicking sound. It may be necessary to repeat this step. If the pilot does not light after 10 seconds, go back to step 3. The control knob should be held down for a MINUTE after pilot ignition.
•If the control knob does not pop out when released,
•If the pilot will not stay lit after two tries, turn the control knob to the "OFF" position and call your service technician or gas supplier.
8.After the pilot has been lit, the burner can be turned on by turning the knob to the "ON" position. Flip the ON/OFF switch to the "ON" position. (This is located to the right on the burner leg and behind the control access cover.)
9.Close control access cover.
TO TURN OFF GAS APPLIANCE ![Manual background](/images/new-backgrounds/52213/5221337xi7.webp)
1.Turn ON/OFF switch to "OFF".
2.Open the control access cover.
3. Turn the valve control knob clockwise to the "Pilot" position, then depress knob and continue turning to "OFF" position.
4. Close control access cover.
Heat & Glo • | 19 |