This option shows both exhaust and inlet air vent pipes attached to the adaptor.
TERMINATION |
CAP |
ADAPTOR |
EXHAUST COLLAR |
INLET AIR COLLAR |
EXHAUST |
VENT PIPE |
V= 14 FT. MINIMUM |
40FT. MAXIMUM |
3 INCH COLLAR |
(Factory installed to |
stainless steel section) |
WARNING: DO NOT |
BLOCK PIPE END WITH |
INSULATION OR ANY OTHER |
SEALING MATERIAL |
STAINLESS STEEL |
PIPE - 3 FT. MIN. |
REQUIRED (INCLUDED) |
INLET AIR |
VENT PIPE |
COLLAR ATTACHMENT |
BRACKET |
Figure 4.
!WARNING: THE EXHAUST VENT PIPE MUST ONLY BE CONNECTED TO THE EXHAUST STARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINATION CAP.
A 3 FOOT SECTION OF STAINLESS STEEL
!FLEXIBLE LINER MUST BE ATTACHED DIRECTLY TO THE EXHAUST COLLAR ON COLLAR SLIDE PLATE.
!THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP OR TERMINATED IN THE CHIMNEY.