Figure 4.

This option shows both exhaust and inlet air vent pipes attached to the adaptor.

TERMINATION

CAP

ADAPTOR

EXHAUST COLLAR

INLET AIR COLLAR

EXHAUST

VENT PIPE

V= 14 FT. MINIMUM

40FT. MAXIMUM

3 INCH COLLAR

(Factory installed to

stainless steel section)

WARNING: DO NOT

BLOCK PIPE END WITH

INSULATION OR ANY OTHER

SEALING MATERIAL

STAINLESS STEEL

PIPE - 3 FT. MIN.

REQUIRED (INCLUDED)

INLET AIR

VENT PIPE

COLLAR ATTACHMENT

BRACKET

Figure 4.

!WARNING: THE EXHAUST VENT PIPE MUST ONLY BE CONNECTED TO THE EXHAUST STARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINATION CAP.

A 3 FOOT SECTION OF STAINLESS STEEL

!FLEXIBLE LINER MUST BE ATTACHED DIRECTLY TO THE EXHAUST COLLAR ON COLLAR SLIDE PLATE.

!THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP OR TERMINATED IN THE CHIMNEY.