3.Reconnect the low voltage wires to the ON/OFF switch.

4.Attach surround assembly by hooking the support brack- et on the locating tabs on top of the gas insert fireplace (see Figure 14.) Once the surround assembly is on the locating tabs, ensure the bottom hooks are resting on the locating pins at the base. Reposition the fireplace if necessary. Refer to surround instructions provided with the decorative surround.

NOTE: PLACE THE THREE INSULATION PIECES INTO THE CAVITIES AT THE BACK OF THE SURROUND BE- FORE POSITIONING THE INSERT INTO THE FACTORY- BUILT OR MASONRY FIREPLACE. THIS INSULATION WILL HELP SEAL FOR COLD AIR LEAKS.

Step 9. Before Lighting the Appliance 12” MAX.

MANTEL

12” MIN.

TOP OF

UNIT

Figure 15

Figure 15 shows the minimum vertical and corresponding maximum horizontal dimensions of mantels or other com- bustible projections above the gas fireplace.

Step 9. Before Lighting the Appliance

Before lighting the appliance, be sure to do the following:

Remove all paperwork from underneath the fireplace.

Review safety warnings and cautions

Read the Safety and Warning Information section at the beginning of this Installers Guide.

Double-check for gas leaks

Before lighting the appliance, double-check the unit for possible gas leaks.

Double-check vent terminations for obstructions.

Before lighting the appliance, double-check the unit for possible obstructions that could be blocking the vent ter- minations.

Double-check for faulty components

Any component that is found to be faulty MUST BE re- placed with an approved component. Tampering with the appliance components is DANGEROUS and voids all war- ranties.

A small amount of air will be in the gas supply lines. When first lighting the appliance, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the appliance will light and will operate normally.

Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines, unless the gas valve has been turned to the OFF position, in which case the air would have to be purged.

NOTE: The fireplace should be run 3 to 4 hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the fireplace for an additional 8 hours. This will help to cure the chemicals used in the paint and logs.

Step 10. Lighting the Appliance

You’ve reviewed all safety warnings, you’ve checked the appliance for gas leaks, you know the vent system is unobstructed, and you’ve checked for faulty components. Now you’re ready to light the appliance.