Heat & Glo LifeStyle PIER-40 owner manual 7 Installing a TCT1175 Terra Cotta Cap

Models: PIER-40

1 52
Download 52 pages 27.91 Kb
Page 35
Image 35
•TCT1175 Terra Cotta Cap

TCT1175 Terra Cotta Cap

 

Place waterproof sealer

Remove 2 screws

under each flange of the

termination cap and on

from front & back

top of each screw to

to lift the top off

help prevent leaks.

 

Termination Cap

The last section of pipe

 

must stop between 2 in.

 

(51 mm) above top of

Collar

chase and 7 in. (178 mm)

below top of chase

2 in. (51 mm)

 

Minimum Height

 

Chase Top

2 in. (51 mm)

 

7 in. (178 mm)

Chase

Chimney

Pipe

Termination cap pipe and chimney section must overlap

1-1/2 in. (38 mm)

Figure 9.7 Installing a TCT1175 Terra Cotta Cap

Heat & Glo • BAY-40, PIER-40 • 34977 • Rev AB 7/12