1.4 FEATURES
•Designed for cooling only.
•Powerful and quiet cooling.
•
1.5 CONTROL LOCATIONS
1.5.1COOLING ONLY MODEL
• OPERATION
FAN SPEED
•Side
•Built in adjustable THERMISTOR and THERMOSTAT.
•Washable
•Compact size.
•Every time you push this button, it advances the setting as follows: {High → Low → Med → High}
Cool | F1 LOW |
Energy | F2 MED |
F3 HIGH | |
Saver |
|
Fan
Timer TEMP
FAN
MODE TIMER SPEED
TIMER
-
REMOTE CONTROL SIGNAL RECEIVER
'F
TEMPERATURE SETTING
•Use this button to automatically control the temperature of the room.
The temperature can be set within a range of 60°F to 86°F by increments of 1°F.
•The setting appears in the display.
POWER POWER
•To turn the air conditioner ON, push this button.
To turn the air conditioner OFF, push the button again.
•This button takes priority over any other button.
•When you first turn it on, the unit is in cool mode, High fan speed, Temperature setting at 72°F.
•You will usually use
•If unit is running, use Timer to set number of hours until
•For your sleeping comfort, once Time is set, the Temperature setting will raise 2°F after 30 min., and once again after another 30 min.
•Push Timer button to advance setting from 1Hour → 2Hours → ... → 12Hours maximum.
-START TIME
•If unit is off, use Timer to set number of hours before unit starts.
•Push Timer button to advance setting from 1Hour → 2Hours → ... → 12Hours maximum.
MODE
-Push this button to shift mode of operation from COOL → ENERGY SAVER → FAN.
-COOL:
•Fan runs continually for normal cooling operation.
-ENERGY SAVER:
•The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed.
-FAN:
•
•VENTILATION
Push the lever to the "CLOSE" position to cool, heat or recirculate room air only.
Pull the lever to the "OPEN" position to exhaust smoke or stale air from the room.
This feature is best used in conjunction with the FAN ONLY position.
CAUTION |
|
When the air conditioner has been operating in the | |
cooling and is turned off or set to the fan | only position, |
wait at least 3 minutes before resetting to the cooling | |
operation again. | PULL OPEN / PUSH CLOSE |