Heat Controller DMH24DB-1, DMC24DB-1 manual For left rear piping

Models: DMC24DB-1 DMH24DB-1

1 35
Download 35 pages 26.68 Kb
Page 21
Image 21

Flaring Work and Connection of Piping

For left rear piping

1.Route the indoor tubing and the drain hose to the required piping hole position.

2.Insert the piping, drain hose, and the connecting cable into the piping hole.

3.Insert the connecting cable into the indoor unit.

Don't connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

4.Tape the drain hose and the connecting cables.

1

2

 

Connecting

 

cable

 

Drain pipe

5.Indoor unit installation

Hang the indoor unit from the hooks at the top of the installation plate.

Insert the spacer etc. between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall.

Connecting the piping to the indoor unit and the drain hose to drain pipe.

1.Align the center of the pipes and sufficiently tighten the flare nut by hand.

2.Tighten the flare nut with a wrench.

Outside diameter

 

Torque

 

 

 

 

 

mm

inch

kg.m

 

lbf.in

Ø6.35

1/4

1.8

 

156.2

Ø9.52

3/8

4.2

 

364.5

3.When extending the drain hose at the indoor unit, install the drain pipe.

Indoor unit

Spacer

Installation plate 8cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit tubing

Flare nut Pipes

 

 

 

 

 

 

 

 

 

 

Open-end wrench (fixed)

Flare nut

Wrench

Connection pipe

Indoor unit tubing

Drain hose

Indoor unit drain hose

Adhesive Vinyl tape (narrow)

Service Manual 21

Page 21
Image 21
Heat Controller DMH24DB-1, DMC24DB-1 manual For left rear piping