Heat Controller HBH 072 - 120, 60 HZR-410A manual Heat Controller, Inc, HBH Series, Submittal Data

Models: 60 HZR-410A HBH 072 - 120

1 30
Download 30 pages 6.08 Kb
Page 20
Image 20
HBH072-120 Dimensional Data

Heat Controller, Inc.

 

 

 

HBH Series

 

Submittal Data

HBH072-120 Dimensional Data

 

 

 

 

 

 

LEFT RETURN STRAIGHT DISCHARGE

RIGHT RETURN STRAIGHT DISCHARGE

 

 

 

A

BSP

BSP

 

 

 

 

 

 

 

 

 

 

B

 

 

A

 

 

 

 

 

 

 

 

 

CBP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

CAP

 

 

F

 

 

 

5

 

 

 

D

1

 

4

 

 

EAP G E

 

 

O

 

EAP

 

 

 

CBP

 

 

 

2

CAP

 

 

 

 

LEGEND

 

CAP

2

CAP

 

 

 

 

 

M

CAP=Compressor Access Panel

 

 

 

 

 

 

 

PQR

CBP=Control Box Panel

 

FRONT

FRONT

 

BSP=Blower Service Panel

 

K

 

EAP=Expansion Valve Access panel

 

 

 

 

 

1=Water Outlet 1-1/4Ó FPT (072-096) 1-1/2Ó FPT (120)

 

 

 

 

 

2=Water Inlet 1-1/4Ó FPT (072-096) 1-1/2Ó FPT (120)

 

SERVICE ACCESS

 

 

 

3=Condensate 3/4Ó FPT

 

 

 

 

 

4=High Voltage 1-1/8Ó [2.9cm] KO

 

 

3Õ (91 cm.) TYPICAL

 

 

 

5=Low Voltage 7/8Ó [2.2cm] KO

 

 

ALL CONFIGURATIONS

NOTES FOR LEGEND:

1.Access is required for all removable panels and installer should take care to comply with all building codes and allow adequate clearance for future field service.

2.Water inlet and water outlet connections are available on either side (left or right) of the unit. Qty (2x) MPT Plugs are shipped loose in a plastic bag tied to the water leg in front of the unit. Installer must plug water inlet/outlet side not being connected to.

3.Condensate drain is available on end opposite compressor.

4.Electrical access is available on either side (left or right) of the front.

5.Electric box is on right side. It can be field converted to left side. Conversion should only be attempted by qualified service technician.

4.3Ó

[10.8cm]

U

T

1.3Ó

[3.3cm]

condensate

BSP

F

G

87Ó

 

HANGER BRACKET DIMENSIONS

 

[221cm]

 

 

1.0Ó

CONTROL BOX

 

 

 

 

[2.54cm]

FRONT

 

FRONT

 

3

PLAN VIEW

34.1Ó

PLAN VIEW

TOP

 

[86.6cm]

 

TOP

 

 

 

 

CONTROL BOX

 

 

S

V

 

V

S

U

LEFT RETURN LEFT VIEW-

 

 

RIGHT RETURN RIGHT VIEW-

1.3Ó

AIR COIL SIDE

 

 

 

AIR COIL SIDE

[3.3cm]

 

 

 

 

 

condensate drain

LEFT RETURN END DISCHARGE

CAP

CAP

RIGHT RETURN END DISCHARGE

CBP

 

FRONT

CAP

 

FRONT

 

 

 

 

 

EAP

 

 

 

 

EAP

 

 

 

 

 

 

 

CAP

 

CBP

BSP

 

 

 

 

E

D

NOTES:

-All dimensions in inches (cm)

-Units require 3Õ (9.1 cm) clearance for water connections, CAP, CSP, EAP and BSP service access.

-Overall cabinet width dimensions does not include filter rail and duct flange.

DIMENSIONAL DATA TABLE ON NEXT PAGE

18

Page 20
Image 20
Heat Controller HBH 072 - 120, 60 HZR-410A Heat Controller, Inc, HBH Series, Submittal Data, HBH072-120Dimensional Data