Inspection
Shipment should be checked against the bill of lading to verify
that all items listed have been received. All parts should be
carefully inspected to determine if any damage was incurred
in shipment.
Any shortage and/or claims for damage should be immediately
reported to the delivering carrier, followed by ling a claim for
shortages and/or damages.
When uncrating, care should be taken to prevent damage.
Heavy equipment should be left on its shipping base until it
has been moved to the nal location.
Rigging and Moving Units
The exact method of handling and setting the unit depends
on available equipment, size of unit, nal location and other
variables. It is the judgement of the riggers and movers to
determine the specic method of handling each unit.
All units are shipped on heavy skids and enclosed in open
crating. Generally, it is advisable to bring the unit as close
to its final location as possible before removing crating.
Units are provided with lifting ears near the four corners. Under
no circumstances should the coil headers or return bends be
used for moving these units.
NOTE FOR ALL MODELS: Spreader bars must be used
(contractor-supplied)� Safety slings should be used when
making lift�
Installation Requirements
NOTE: Installation and maintenance to be performed only
by qualied personnel who are familiar with local codes
and regu lations and are experien ced wi th th is ty pe of
equipment�
CAUTION: Sharp edges and coil surfaces are a potential
injury hazard� Avoid contact with them�
WARNING: This equipment may contain a substance that
harms public healt h and the envi ronment by dest roying
ozone in t he upp er atm osph ere � V enti ng of cer tai n
refriger ants to t he at mosphe re m ay be ille gal i n you r
location� Refr igerant recove ry d evices should be used
when insta lling o r servi cing th is prod uct� C onsult y our
local codes for requirements in your location�
WARNING: Refri gerant can be harm ful if i t is inh aled�
Refrige rant must be u sed and recove red respon sibly�
Failure to follow this warning may result in personal injury
or death�

Unit Location

Units are designed for outdoor application and may be
mounted on a roof or concrete slab (ground-level installation).
Concrete slabs used for unit mounting should be installed level
and be properly supported to prevent se ttling. A one -piece
concrete slab with footings extending below the frost line
is recommended.
Roof-mounted units should be installed level on steel channels
or an I-beam frame to support the unit above the roof. Use of
vibration pads or isolators is recommended. The roof must be
strong enough to support the weight of the unit.
2 Part # 2500018
Installation and Operations Manual
© 2007 Heatcraft Refrigeration Products LLC
Figure 2: Leg Mounting
Figure 1: Suggested Rigging