Heatcraft Refrigeration Products BN-LOPTB manual Hot Gas Reverse Cycle Kits

Models: BN-LOPTB

1 20
Download 20 pages 14.49 Kb
Page 13
Image 13
Hot Gas Reverse Cycle Kits

Hot Gas Reverse Cycle Kits

HGT 6 FPI

 

Shipped-loose

 

 

Factory-installed

 

TXV Bypass Assembly Kits

TXV Bypass Assembly Kits

SQE/SBF

EG

HFESC

SQE/SBF

EG

HFESC

035-075

090-160

180-280

50169210

50169211

50169212

50169213

50169214

50169215

50169216

50169217

50169218

52733701

52733702

52733703

52733704

52733705

52733706

52733707

52733708

52733709

HGT 4 FPI

041-080

102-204

235

50169210

50169211

50169212

50169213

50169214

50169215

50169216

50169217

50169218

52733701

52733702

52733703

52733704

52733705

52733706

52733707

52733708

52733709

Shipped-loose

Factory-installed

Drain Pan Loop

Suction Line

Drain Pan Loop

Suction Line

Check Valve Kit

Check Valve Kit

Check Valve Kit

Check Valve Kit

HGT 6 FPI

035-065

075-140

160-280

50169304

50169305

50169306

50169604

50169605

50169606

52733601

52733602

52733603

52733801

52733802

52733803

HGT 4 FPI

041

068-102

136-235

50169304

50169305

50169306

50169604

50169605

50169606

52733601

52733602

52733603

52733801

52733802

52733803

Recommendation is that both check valve kits are ordered: (For hot gas models with the hot gas loop drain pan ONLY)

NOTE: The drain pan check valve kit can be ordered as an independent item. But the suction line check valve kit must be ordered with the drain pan check valve kit in order to complete the piping.

NOTE: When using the hot gas units with a hot gas loop drain pan on 0°F applications and below, an insulated drain pan is required.

The hot gas unit coolers can be used in reverse cycle hot gas defrost systems using multiple evaporators connected to one condensing unit. Generally, not more than one-third of the system defrosts at one time.

During the reverse cycle defrost, the reversing valve; located in the compressor discharge line, diverts hot gas through the suction line to the evaporator. See piping view in Figure 1. The suction line check valve directs the hot gas through the drain pan loop which prevents condensate in the pan from freezing. The hot gas exits the loop at the pan loop outlet header and enters the evaporator through the check valve assembly. As the hot gas defrosts the coil, heat is removed from the hot gas and eventually it condenses into a liquid and exits the coil at the distributor sideport. The liquid then flows through the check valve of the thermostatic expansion valve bypass assembly, around the thermostatic expansion valve, and into the system liquid line. The liquid refrigerant then feeds other evaporators on the cooling cycle, evaporates, and returns to the compressor through their suction lines.

13