Horizontal Discharge

Electrical Data

Medium Temperature – R-404A/507

 

 

Voltage

Compressor

 

Condenser

 

Beacon II™ or

 

Remote Loads

 

 

 

Supply ^

 

Fan Motors

 

Air Defrost

 

 

 

 

 

 

 

 

 

 

 

 

Unit Model

Compressor

 

 

 

 

 

 

 

 

 

 

 

Electric Defrost

 

Number

Model

60 Hz

RLA

LRA

Qty.

 

HP

FLA

MCA

MOP††

Evap. Defrost

System System

 

 

 

 

 

 

 

 

 

 

 

 

Fan

Heater

 

 

 

 

 

 

 

 

 

 

 

 

Amps

Amps

MCA

MOP††

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CB*0551M6C

4C0969SH

208-230/3

26.5

163.0

2

 

1/3

 

5.4

38.5

60

 

 

 

 

CB*0551M6D

4C0969SH

460/3

12.8

66.5

2

 

1/3

 

3.8

19.8

30

 

 

 

 

CB*0551M6E

4C0969SH

575/3

8.3

48.0

2

 

1/3

 

2.4

12.8

20

 

 

 

 

CB*0751M6C

4C1145SH

208-230/3

29.0

215.0

2

 

1/3

 

5.4

41.7

70

 

 

 

 

CB*0751M6D

4C1145SH

460/3

13.8

88.0

2

 

1/3

 

3.8

21.1

35

 

 

 

 

CB*0751M6E

4C1145SH

575/3

10.3

63.5

2

 

1/3

 

2.4

15.3

25

CONTACT FACTORY FOR SYSTEM

CB*0911M6C

4C1385SH

208-230/3

32.7

215.0

2

 

3/4

 

8.8

49.7

80

 

ELECTRICAL RATINGS

CB*0911M6D

4C1385SH

460/3

16.3

88.0

2

 

3/4

 

4.4

24.8

40

 

 

 

 

CB*0911M6E

4C1385SH

575/3

13.1

63.5

2

 

3/4

 

3.6

20

30

 

 

 

 

CB*1001M6C

4C1480PH

208-230/3

38.5

222.0

2

 

3/4

 

8.8

56.9

90

 

 

 

 

CB*1001M6D

4C1480PH

460/3

19.2

111.0

2

 

3/4

 

4.4

28.4

45

 

 

 

 

CB*1001M6E

4C1480PH

575/3

15.4

89.0

2

 

3/4

 

3.6

22.9

35

 

 

 

 

Low Temperature – R-404A/R-507

 

 

Voltage

Compressor

 

Condenser

 

Beacon II™ or

 

Remote Loads

 

 

 

Supply ^

 

Fan Motors

 

Air Defrost

 

 

 

 

 

 

 

 

 

 

 

 

Unit Model

Compressor

 

 

 

 

 

 

 

 

 

 

 

Electric Defrost

 

Number

Model

60 Hz

RLA

LRA

Qty.

 

HP

FLA

MCA

MOP††

Evap. Defrost

System System

 

 

 

 

 

 

 

 

 

 

 

 

Fan

Heater

 

 

 

 

 

 

 

 

 

 

 

 

Amps

Amps

MCA

MOP††

CB*0401L6C

4C0969SL

208-230/3

16.7

142.0

1

 

1/3

 

2.7

23.6

40.0

 

 

 

 

CB*0401L6D

4C0969SL

460/3

9.0

58.0

1

 

1/3

 

1.9

13.2

20.0

 

 

 

 

CB*0401L6E

4C0969SL

575/3

7.0

51.5

1

 

1/3

 

1.2

10.0

15.0

 

 

 

 

CB*0551L6C

4C1145SL

208-230/3

19.4

163.0

1

 

1/3

 

2.7

27.0

45.0

 

 

 

 

CB*0551L6D

4C1145SL

460/3

10.6

66.5

1

 

1/3

 

1.9

15.2

25.0

 

 

 

 

CB*0551L6E

4C1145SL

575/3

8.7

48.0

1

 

1/3

 

1.2

12.1

20.0

 

 

 

 

CB*0601L6C

4C1385SL

208-230/3

24.9

215.0

2

 

1/3

 

5.4

36.5

60.0

 

 

 

 

CB*0601L6D

4C1385SL

460/3

14.2

88.0

2

 

1/3

 

3.8

21.6

35.0

 

 

 

 

CB*0601L6E

4C1385SL

575/3

10.8

63.5

2

 

1/3

 

2.4

15.9

25.0

 

 

 

 

CB*0611L6C

4C1480PL

208-230/3

24.4

150.0

2

 

1/3

 

5.4

35.9

60.0

 

 

 

 

CB*0611L6D

4C1480PL

460/3

12.2

75.0

2

 

1/3

 

3.8

19.1

30.0

 

 

 

 

CB*0611L6E

4C1480PL

575/3

9.6

60.0

2

 

1/3

 

2.4

14.4

20.0

CONTACT FACTORY FOR SYSTEM

CB*0751L6C

4C1761PL

208-230/3

28.2

180.0

2

 

1/3

 

5.4

40.7

60.0

 

ELECTRICAL RATINGS

CB*0751L6D

4C1761PL

460/3

14.1

90.0

2

 

1/3

 

3.8

21.4

35.0

 

 

 

 

CB*0751L6E

4C1761PL

575/3

12.2

72.0

2

 

1/3

 

2.4

17.7

30.0

 

 

 

 

CB*1001L6C

4C2067PL

208-230/3

34.6

222.0

2

 

1/3

 

5.4

48.7

80.0

 

 

 

 

CB*1001L6D

4C2067PL

460/3

17.3

111.0

2

 

1/3

 

3.8

25.4

40.0

 

 

 

 

CB*1001L6E

4C2067PL

575/3

14.4

89.0

2

 

1/3

 

2.4

20.4

30.0

 

 

 

 

CB*1201L6C

4C2397PL

208-230/3

39.7

252.0

2

 

3/4

 

8.8

58.4

90.0

 

 

 

 

CB*1201L6D

4C2397PL

460/3

19.9

126.0

2

 

3/4

 

4.4

29.3

45.0

 

 

 

 

CB*1201L6E

4C2397PL

575/3

15.9

101.0

2

 

3/4

 

3.6

22.5

35.0

 

 

 

 

CB*1301L6C

4B2707PL

208-230/3

43.6

294.0

2

 

3/4

 

8.8

63.3

100.0

 

 

 

 

CB*1301L6D

4B2707PL

460/3

21.8

147.0

2

 

3/4

 

4.4

31.7

50.0

 

 

 

 

CB*1301L6E

4B2707PL

575/3

17.3

117.0

2

 

3/4

 

3.6

25.2

40.0

 

 

 

 

*= T for Outdoors, N for Indoors, S for Beacon II

^Consult factory for 50Hz applications.

† MCA = Minimum Circuit Ampacity

†† MOP = Maximum Overcurrent Protection

‡ Condensing unit data plate ratings will be based on actual system match.