Heatcraft Refrigeration Products TL, TA, KMK, VA Model BTO, Twin Flow Reach-InUnit Cooler Features

Models: U KMK C BBL RAMK BBM VA BTO TL TA

1 12
Download 12 pages 50.55 Kb
Page 10
Image 10
Model BTO

Model BTO

Twin Flow Reach-In Unit Cooler

Features

Compact two-way design with medium velocity air flow

Mounts flush to the ceiling and draws air in through the fan and discharges out both sides

Air pattern reduces air loss when doors are opened and the medium velocity reduces product drying

Textured aluminum cabinet

Stainless steel fasteners

Molded Lexan® fan guards

Drain pan and fan panel is easily removed for installation and servicing

Optional Bohn-Kote® coated coil available (Model BTOK) for optimum protection in corrosive environments

Coils are constructed of copper tubing with aluminum fins

Expansion valve mounts inside the cabinet

Internal junction box is provided for electrical connection

Motors are thermally protected and permanently lubricated

All models are UL listed for the US and Canada

UL classified to NSF standards

Sweat inlet connection to reduce leaks

(flare connection available as a ship loose option)

Application

Model BTO is ideal for temperatures of 35°F and higher. Box temperatures are kept more constant throughout and fresh products last longer. Seven sizes are available with BTUH from 900 to 5,500 at 10° TD.

Larger BTO sizes are suitable for large reach-in and small step-in or walk-in coolers.

Nomenclature

BTO K 09 A G

Twin Flow Unit Cooler

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vintage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bohn-Kote® Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = 115/1/60

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B = 208-230/1/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 15. Performance and Electrical Data

 

BTUH

BTUH

 

 

Motor Data

 

Connections (in.)

Approx.

Model

CFM

Qty.

115/1/60

208-230/1/60

Coil Inlet

Suction

Drain

Ship Wt.

10°F TD

15°F TD

 

Total FLA

Total FLA

OD

ID

OD

(lbs.)

 

 

 

 

 

BTO09

900

1,350

130

1

0.8

0.4

1/2

1/2

1/2

12

BTO13

1,300

1,950

240

2

1.6

0.8

1/2

1/2

1/2

14

BTO18

1,800

2,700

255

1

1.0

0.5

1/2

1/2

1/2

15

BTO25*

2,500

3,750

460

2

2.0

1.0

1/2

1/2

1/2

23

BTO35*

3,500

5,250

425

2

2.0

1.0

1/2

1/2

1/2

24

BTO45*

4,500

6,750

550

2

2.0

1.0

1/2

1/2

5/8

34

BTO55*

5,500

8,250

730

1

2.1

1.1

1/2

1/2

5/8

34

Models 25, 35, 45 and 55 use external equalized expansion valve

Table 16. Physical Data

Model

 

 

 

 

 

 

Dimensions (in.)

 

 

 

 

 

 

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

 

BTO09

16-1/8

19-1/8

7-9/16

4

2-5/16

9-9/16

2-3/4

4-7/8

4-1/2

8-5/8

2-1/2

2-5/8

4-9/16

10

7/8

BTO13

16-1/8

19-1/8

7-9/16

4

2-5/16

9-9/16

2-3/4

5-3/4

4-1/2

8-5/8

2-1/2

2-5/8

4-9/16

10

7/8

BTO18

16-1/8

19-1/8

7-9/16

4

2-5/16

9-9/16

2-3/4

5-3/4

4-1/2

8-5/8

2-1/2

2-5/8

4-9/16

10

7/8

BTO25

18-1/8

26-1/8

11-1/16

4

2-5/16

13-1/16

2-3/4

6-3/4

5-1/2

12-1/8

3-1/2

2-5/8

8-1/16

10

7/8

BTO35

18-1/8

26-1/8

11-1/16

4

2-5/16

13-1/16

2-3/4

6-3/4

5-1/2

12-1/8

3-1/2

2-5/8

8-1/16

10

7/8

BTO45

21-1/8

29-1/8

8-3/16

7-3/4

3-7/16

10-5/8

3-1/2

9-1/4

8

13-5/8

5-15/16

4-1/4

7-9/16

14

1-3/4

BTO55

21-1/8

29-1/8

8-3/16

7-3/4

3-7/16

10-5/8

3-1/2

8-1/2

8

13-5/8

5-15/16

4-1/4

7-9/16

14

1-3/4

Diagram 8. Dimensions

10

Page 10
Image 10
Heatcraft Refrigeration Products TL, TA Model BTO, Twin Flow Reach-InUnit Cooler Features, Performance and Electrical Data