TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSE | SOLUTION | ||
|
|
|
|
|
Light will not come on. | 1. | Light switch is turned off. | 1. | Turn light switch on. |
| 2. | Flood lamp is loose or burned out. | 2. | Check flood lamp and replace if burned out. |
| 3. | Fuse is blown or circuit breaker is turned off. | 3. | Replace fuse or turn circuit breaker on. |
| 4. | Daylight | 4. | Recheck after dark. |
| 5. | Incorrect circuit wiring, if this is a new installation. | 5. | Verify wiring is correct. |
| 6. | Sensor does not detect objects in desired area. | 6. | |
|
|
|
| sitivity. |
|
|
|
|
|
Light comes on in day- | 1. | Light control may be installed in a relatively dark | 1. | Relocate light fixture to another junction box with |
light. |
| location. |
| increased amount of daylight. |
| 2. | Light control is in TEST. | 2. | Set control switch to 1, 5, or 10 minutes. |
|
|
|
|
|
Light comes on for no | 1. | Light control may be sensing small animals or auto- | 1. | |
apparent reason. |
| mobile traffic. |
|
|
| 2. | Range is set too high. | 2. | Reduce range. Turn Range Boost off. |
| 3. | DualBrite® timer is on. | 3. | Turn DualBrite® Timer off. |
Light turns off too late in | Light control may be installed in a relatively dark loca- | Relocate light control, or use 3 hr. or 6 hr. setting. | ||
tion. |
|
| ||
|
|
|
|
|
Light stays on continu- | 1. | A flood lamp is positioned too close to the light control | 1. | Reposition the flood lamp away from the light control |
ously. |
| or pointed at nearby objects that cause heat to trigger |
| or nearby objects. |
|
| the light control. |
|
|
| 2. | The light control may be picking up a heat source | 2. | Reduce range. |
|
| like an air vent, dryer vent, or brightly painted, heat- |
| off. |
|
| reflective surface. |
|
|
| 3. | Light control is in manual mode. | 3. | Switch light control to AUTO. |
|
|
|
|
|
Light flashes on and | 1. | Heat or light from the flood lamp may be turning the | 1. | Reposition the flood lamp away from the light con- |
off. |
| light control on and off. |
| trol. |
| 2. | Heat being reflected from other objects may be turn- | 2. | Reposition light control. |
|
| ing the light control on and off. |
|
|
| 3. | Light control is in the TEST mode and warming up. | 3. | Flashing is normal under these conditions. |
|
|
| ||
Light flashes once, then | Light control is detecting its own light. | Reposition flood lamp to keep area below the light | ||
stays off in manual |
|
| control relatively dark. | |
mode. |
|
|
|
|
|
|
|
|
|