Heath Zenith 5310 manual Installation, Wire the Light Control, Mount the Light Control

Models: 5310

1 12
Download 12 pages 34.15 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

Caution: Risk of fire. This fixture is designed for wall mounting only. DO NOT install on a ceiling or soffit.

For easy installation, select an existing light with a wall switch for replacement.

Attach the lamp arm to the backplate arm and secure with the long bolt.

Note:When tightening the arm screw, pull on the wires to make sure the wires are not pinched by the joint.

Drill out the holes if needed to mount the backplate to the junction box.

Wire the Light Control

Wire the Light Control WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

The S-hook can be used to hold the fixture while wiring. The small end of the hook can be inserted into a hole in the junction box. The large end goes around the “neck” of the fixture.

Route the light control’s wires through the large hole in the gasket.

Twist the junction box wires and fixture wires together as shown. Secure with a wire connector.

Black to Black

Cover Plate

Gasket

Mount the Light Control

Align the light control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws.

If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant.

+/- 4°

MOUNT HORIZONTALLY

The halogen light must be mounted horizontally (+/- 4°).

Bulb Installation and Re-lamping

When re-lamping, turn power off and let the fixture cool.

CAUTION to avoid fire or burn hazards:

Allow fixture to cool before touching.The bulb and fixture operate at high temperatures.

Keep fixture at least 2" (51 mm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).

Re-lamp with type T halogen, 500 W max., 120 VAC lamp only.

Remove glass cover and remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.

To insert the new bulb, push the bulb into the right socket so the bulb fits completely into the left socket.

Check that the bulb is seated properly.

Re-install the glass cover.

For proper operation and safety,the light fixture must be above the sensor and the sensor head must be rotated so that the controls are on the bottom.

White to White

Junction box ground wire to green ground wire on fixture.

598-1323-01

Page 2
Image 2
Heath Zenith 5310 manual Wire the Light Control, Mount the Light Control, Bulb Installation and Re-lamping