TEST AND ADJUSTMENT
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period be- fore it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

RANGE

ON-TIME

10 5 1 TEST

MIN

MAX

 

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

180°

8 ft.

(2.4 m)

70 ft.

(21 m)

Maximum Range

Maximum

 

Coverage Angle

The detector is less sensitive to motion directly towards it.

Loosen the clamp screw in the

Clamp

sensor ball joint and gently

Screw

rotate the sensor.

 

Walk through the coverage

Ball

area noting where you are

Joint

when the lights turn on. Move

 

the sensor head up, down,

 

or sideways to change the

Aim Sensor

coverage area.

Adjust the RANGE as needed.

Down for Short

RANGE set too high may

Coverage

increase false triggering.

 

Secure the sensor head’s

aim by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after

motion is detected (1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature]

Sensing Angle. . . . Up to 180°

Electrical Load. . . . Up to 500 Watt Maximum Incandescent

Power Requirements. . 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Replacement lamp. . . T 500W (or less) halogen 120

VAC

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.