Heath Zenith 5716 manual Replacement Sensor Head, Operation, Model, DualBrite, On-Time, Lamp Mode

Models: 5716

1 16
Download 16 pages 7.65 Kb
Page 1
Image 1
DualBrite®

DualBrite®

Replacement Sensor Head

AUTO

Put the ON-TIME switch in the 1, 5,

ON-TIME

or 20 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

 

 

 

 

 

 

 

MANUAL MODE

 

 

 

 

 

 

Model 5716

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Three lamp modes available: Normal, Soft, or Flash.

Patented DualBrite® Timer.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

Manual mode only works at night be- cause daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON- TIME switch in the 1, 5, or 20 position.

1 Second OFF

then...

... back on.

Requirements

Not for use with fluorescent lights.

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Install sensor in accordance with local codes.

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Sec

x

x

 

 

 

 

Normal

1, 5, 20 min.

 

x

 

 

 

 

Manual

Until Dawn*

 

x

 

 

 

 

Accent

3, 6 Hr. to Dawn

 

x

 

* resets to Auto Mode at dawn.

 

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put ON-TIME switch on ON-TIME

DualBrite®

the sensor bottom to

 

 

 

 

 

 

 

 

 

 

 

TEST and the DualBrite®

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

Off 3 6 Dusk to

switch OFF.

 

 

 

 

 

 

 

 

 

Dawn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP MODE

 

 

 

 

 

 

 

 

 

 

 

Put the LAMP MODE switch

 

 

LAMP MODE

in the Normal, Soft, or Flash

NORMAL SOFT FLASH

 

 

 

 

 

 

 

position.

Mode Switching Summary

 

TEST

 

 

 

 

Move ON-TIME Switch to 1,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5, or 20 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*
MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

DualBrite® TIMER

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature.The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.

LAMP MODES

There are three lamp modes (light turn-on effects) avail- able when motion is detected:

NORMAL - Light instantly comes on.

SOFT - Light starts dim and gradually increases to full brightness. Light gradually dims to half-bright, pauses, and then continues dimming to off when motion is no longer detected and after selected ON-TIME.

FLASH - Light flashes on then off twice before turning on full brightness.

© 2007 HeathCo LLC

598-1307-01

Page 1
Image 1
Heath Zenith 5716 manual Replacement Sensor Head, Operation, Model, DualBrite, On-Time, Lamp Mode, Test, Auto, Manual Mode