TEST AND ADJUSTMENT
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion.When first turned on or when switching modes wait 1 1/2 minutes.

Turn the RANGE control to the medium position (halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position.

LAMP MODE

NORMAL SOFT FLASH

 

 

 

 

 

ON-TIME

DUAL BRITE™

MIN

 

 

 

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

OFF 3 6 DUSK TO

RANGE

 

 

 

MINUTES

 

HOUR DAWN

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heat- ing vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or unwanted traffic may trigger the control.

Nearby large,light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

270°

8 ft.

(2.4 m)

70 ft.

100 ft.

 

(21 m)

(30.5 m)

 

 

Boosted

 

Maximum Range

Maximum

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

Loosen the clamp screw in the

Clamp

sensor ball joint and gently rotate

Screw

the sensor.

 

Walk through the coverage area

Ball

noting where you are when the

Joint

lights turn on. Move the sensor

 

head up, down, or sideways to

 

change the coverage area.Keep

 

the sensor at least 1" (2.5 cm)

 

away from the lamps.Aim Sensor

Adjust the RANGE as needed.

Down for Short

RANGE set too high may

Coverage

increase false triggering.

 

Secure the sensor head's aim by tightening the clamp screw.

Do not overtighten the screw. Set the amount ofTIME you want

the lights to stay on after motion is detected (1, 5, or 20 minutes).

Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

Set the LAMP MODE switch to the desired light turn- on effect (Normal, Soft, Flash).

SPECIFICATIONS

Range . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost.[varies with surrounding temperature]

Sensing Angle. . . . Up to 270°

Electrical Load. . . . Up to 300 Watts Maximum Incan- descent

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL MODE

Lamp Modes. . . . Normal, Soft, Flash Time Delay . . . . . 1, 5, 20 minutes