4598-1315-02
Motion
Motion
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Least Sensitive Most Sensitive
Sensor
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights tur n on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 2" (51 mm) away from
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
❒ Set the DualBrite® switch to the amount of time
after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).
❒ Set the LAMP MODE switch to the desired light
turn-on effect (Normal, Soft, Flash).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or unwanted traffic may trigger
the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
270°
Maximum Range Maximum
Coverage Angle
100 ft.
(30.5 m)
Boosted
LAMP MODE
NORMAL SOFT FLASH
ON-TIME DUAL BRITE™
TEST 1 5 20
MINUTES
OFF 3 6 DUSK TO
HOUR DAWN
MAXMIN
RANGE
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
NOTE: Meets the ENERGY STAR® guidelines when
DualBrite® function is off and ON-TIME is 1 or 5 mi-
nutes.
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite® to OFF,
and the ON-TIME control to the TEST position.
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).