Bulb Installation

NOTE: When re-lamping, turn power off and let the fixture cool.

To remove lamp shade, loosen set screw 2 full turns with a small flat-head screwdriver.Turn shade counterclockwise and remove.

To remove bulb, pull straight out of fixture.

To replace bulb, firmly push bulb pins into lamp socket until completely seated.

To reinstall lamp shade, place shade on fixture and align notches on shade with tabs on fixture. Turn clockwise. Tighten set screw firmly.

Mount the Light Control

Place the mounting bolt through the front of the junction box cover. Push the small gasket hole over the mounting screw.

Make sure the wire connectors and wires are inside the junction box. Align the mounting screw with the center hole in the mounting strap.Secure the fixture to the mounting strap.

Push the rubber plug firmly into place.

If not installed on a weatherproof box, caulk the wall plate and mounting surface with silicone.

Wire the Light Control

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

Install mounting strap to junction box using screws

appropriate for your junction box.

The plastic hanger can be used to hold the fixture

while wiring. The small end of the plastic hanger

can be threaded through the hole in the center of

the cover plate. The small end then goes into one

Lamp Shade

Lock Nuts

Lens

Push the Rubber Plug over the Mounting Screw.

Set Screw

Keep lamps at least 2" (51 mm) from the sensor.

of the slots on the mounting strap.

Thread all fixture wires through the large holes in

the gasket as shown.

Connect the junction box wires to the light fixture

wires as shown. Twist together and secure with

wire connectors.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting.

Adjust lamp shades by loosening the set screws several turns, turn shades counterclockwise and remove.Reinstall the shades in the desired position and tighten set screws.

Black to Black

Mounting Strap

White to White

Rubber

Plug

Mounting

Bolt

Gasket

Junction box ground wire to green ground screw on fixture.

598-1315-02

Page 3
Image 3
Heath Zenith 5797 manual Bulb Installation, Mount the Light Control, Wire the Light Control