WARNING: Turn power off at the circuit breaker before wiring.
Installing Sensor
Removing Control Panel Cover
1.Remove the decorative cover plate (secured by two small screws).
2.Press in with screwdriver as shown in Figure 2. Swing control panel cover out to remove.
ON
OFF | AUTO |
|
Control Panel
Cover
Figure 2 - Removing Control Panel Cover
Typical Installation
1.Remove existing wall switch from junction box.
2.Connect electrical leads of sensor as shown in Figure 3. Before installing sensor into junction box, make sure there is no wire exposed at each connection.
3.Mount sensor into junction box using two large mounting screws provided.
4.For test purposes, use a small screwdriver to turn the TIME control fully counterclockwise and the LIGHT control fully clockwise. Turn the power back on at the circuit breaker.
5.Set mode selection switch to the AUTO posi- tion. When unit stabilizes (about 1 minute), the sensor is ready to detect motion. If sensor detects motion, the lights will turn on. The lights will turn off 5 seconds after motion is no longer detected.
Control
Panel
5 10
+
| To Lighting Load |
Black | Neutral |
| Return |
| Lighting Load |
| Green ground wire to |
| junction box screw or |
115
Test20
T I M E L I G H T
Mode
Selection
Switch
| grounding wire. |
Black | Line |
| “Hot” |