4
598-1208-00

TESTING

1. Turn on the circuit breaker and light switch.
Note:
Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on
wait 1 1/2 minutes.
2. Set the ON-TIME switch to the TEST position
and the Dual Brite® switch to the OFF position.
3. Walk through the coverage area noting where
you are when the lights turn on. In TEST
mode, light will stay on for only 5 seconds then
turn off.
4. Adjust the SENSITIVITY to increase or de-
crease the range as needed. Too much sensi-
tivity may cause false triggering due to heat
sources in the coverage area (see Adjustment
of Coverage Area or Troubleshooting section).

INSTALL FIXTURE BASE TO

JUNCTION BOX

1. Push wires into the junction box.
2. Slide light fixture base onto fixture screws and
tighten decorative nuts snugly against the base.
3. Install four candelabra base light bulbs (25
Watts maximum each).
4. Refer to TESTING section before installing
cover.
5. After switches are set and testing is complete,
use the 2 decorative nuts to install the cover.
DUAL BRITE
®
ON-TIME
TEST 1 5 10 MIN
OFF 3 6 DUSK
TO DAWN
DualBrite®
ON-TIME
DUSK
OFF
3
HR
6
HR
TO DAW
N
TEST 1 5 10 MIN
Sensor
Lens
5. Set the amount of ON-TIME you want the light
to stay on after motion is detected (1, 5, or 10
minutes).
6. Set the amount of time you want the light to
stay on in the Accent mode (Off, 3 hours, 6
hours, or dusk-to-dawn).
SENSITIVITY
+
+
SENSITIVITY
DUAL BRITE
®
ON-TIME
TEST 1 5 10 MIN
OFF 3 6 DUSK
TO DAWN
Fixture Screw
Junction Box
Decorative Nut
25 Watt Candelabra
Base Bulb

Maximum Range Coverage Angle*

(Top View)

360°
30 Feet (9.1 m)
in all Directions
* Without lens shield installed.
8 ft. (2.4 m)