Heath Zenith manual Motion Sensor Decorative Lighting Control, Operation, Model SL-5210, Test

Models: SL-5210

1 12
Download 12 pages 19.39 Kb
Page 1
Image 1
Motion Sensor

Motion Sensor

Decorative Lighting

Control

Model SL-5210

Features

• Turns on lighting when motion is detected.

OPERATION

Mode:

On-Time:

Works:

Day

Night

 

 

 

 

 

Test

5 Sec

 

x

x

 

 

 

 

 

Normal

1, 5, 10 min.

 

 

x

 

 

 

 

 

Manual

Until Dawn*

 

 

x

 

 

 

 

 

* resets to Auto Mode at dawn.

Note: When first turned on wait about 11/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom of the ON-TIME

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

Requirements

The light control requires 120-volts AC.

If you want to use Manual Override, the control must be wired through a wall switch.

Some codes require installation by a qualified electrician.

Switch Module mounts into a standard 4" x 4" junction box.

sensor in the TEST position.

AUTO

Put the ON-TIME switch in the 1, 5, or 10 minute position.

MANUAL MODE

10 5 1 TEST

ON-TIME

10 5 1 TEST

The SL-5210 package includes:

The Sensor Module and Switch Module

Three wire nuts

Two sensor module screws

Typical Installation

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second

 

then back on to toggle between AUTO and

1 Second OFF

MANUAL MODE.

then...

Switch Mod-

ule In Junction

Box Behind Light Fixture

Existing Light Fixture

Sensor Cord

Sensor Module

Drip Loop Model SL-5210

Manual mode works only with the ON-TIME
switch in the 1, 5, or 10 position.

 

 

 

 

 

 

... back on.

 

Mode Switching Summary

 

 

 

 

 

 

 

TEST

 

Move ON-TIME Switch to 1,

 

 

 

 

 

 

 

5, or 10 minutes
AUTO FeaturesFlip switch off for one second then back on*MANUAL MODE

NOTE: The Drip Loop is neccessary to prevent rain from running down the cord to the Sensor Module.

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time (11/2 min.) the control will be in the AUTO mode.

© 2007 HeathCo LLC

595-4991-07

Page 1
Image 1