Image 3
TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

The detector is less sensitive to motion directly towards it and more sensitive to across motion.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching modes, wait 1 1/2 minutes.

Motion

Motion

Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

Sensor

Least Sensitive

Most Sensitive

ON-TIMESENS

10 5 1 TEST

 

 

 

 

 

 

 

MIN MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating

 

vents and air conditioners. These heat sources could

 

cause false triggering.

Areas where pets or traffic may trigger the control.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.

Adjust the SENSITIVITY as needed.Too much sensitivity may increase false triggering.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Aim Sensor Down for Short Coverage
Aim Sensor Higher for Long Coverage

Nearby large,light-colored objects reflecting daylight may

trigger the shut-off feature. Do not point other lights at the

sensor.

110°

5 ft.

 

60 ft.

Maximum Range

Maximum

 

Coverage Angle

SPECIFICATIONS

Range . . . . . . . . Up to 60 feet (varies with surround- ing temperature).

Sensing Angle. . . . . Up to 110°

Electrical Load. . . . . Up to 500 Watts Maximum, Incan-

descent

Power Requirements. . . 120 VAC, 60 Hz

Operating Modes. . . . TEST, AUTO and MANUAL OVER-

RIDE

Time Delay . . . . . . 1, 5, 10 minutes Sensitivity . . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.