TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
The detector is less sensitive to motion directly towards it and more sensitive to across motion.
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching modes, wait 1 1/2 minutes.
Motion
Motion
❒Turn the SENSITIVITY (SENS) control to the mid position and the
Sensor
Least Sensitive | Most Sensitive |
ON-TIME SENS
10 5 1 TEST |
|
|
|
|
|
|
| MIN MAX |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bottom of Sensor
Avoid aiming the control at:
• | Objects that change temperature rapidly, such as heating |
| vents and air conditioners. These heat sources could |
| cause false triggering. |
• | Areas where pets or traffic may trigger the control. |
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.
❒Adjust the SENSITIVITY as needed.Too much sensitivity may increase false triggering.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
Aim Sensor Down for Short Coverage
Aim Sensor Higher for Long Coverage
• Nearby |
trigger the |
sensor. |
110°
5 ft.
| 60 ft. |
Maximum Range | Maximum |
| Coverage Angle |
SPECIFICATIONS
Range . . . . . . . . Up to 60 feet (varies with surround- ing temperature).
Sensing Angle. . . . . Up to 110°
Electrical Load. . . . . Up to 500 Watts Maximum, Incan-
descent
Power Requirements. . . 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO and MANUAL OVER-
RIDE
Time Delay . . . . . . 1, 5, 10 minutes Sensitivity . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.