Heath Zenith SL-5211 manual Installation, Mounting Sensor, Drip Loop

Models: SL-5211

1 8
Download 8 pages 46.62 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

.

Before proceeding with the installation, TURN OFF

THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX to avoid electrical shock.

There are two types of decorative fixtures that the Instant Light Control should be used with as shown here.

‘A’ shows a fixture with the wire going under the top cover. ‘B’ shows a fixture with a open bottom and the wire going through the bottom.

Drip

Loop

‘A’

‘B’

‘B’

 

Seal With Weather-

 

Proof Sealant

 

Drip Loop

Plug the sensor cord into the switch module. The sensor cord's plug is polarized for proper installation.

IMPORTANT: When installing the sensor, make sure the wire comes out the bottom of the bracket and the wire has a drip loop (as shown below) to help prevent water from entering the sensor head.

NOTE: The Drip Loop is neccessary to prevent rain from running down the cord to the Sensor Module.

Open the top of the light fixture if it is necessary. Remove the light bulb.

Screw in the lamp module and replace the bulb.

Drip Loop

Mounting Sensor

Mount the sensor approximately five feet above the ground.

Place the sensor below or beside the lighting fixture so that the light from the decorative fixture will not hit the sensor. Secure the sensor to the wall with the screws provided. It may be necessary to tilt the sensor head up slightly when mounting.

NOTE: Mounting the sensor above the light fixtures may increase false triggering.

2

595-4238-07

Page 2
Image 2
Heath Zenith SL-5211 manual Installation, Mounting Sensor, Before proceeding with the installation, TURN OFF, Drip Loop