Heath Zenith SL-5309 manual Motion Sensor Quartz Security Light, Operation, Installation, On-Time

Models: SL-5309

1 12
Download 12 pages 57.97 Kb
Page 1
Image 1
Motion Sensor Quartz Security Light

Motion Sensor Quartz Security Light

Model SL-5309

The Motion Sensor Quartz Security Light turns on 300 watts of quartz-halogen lighting when motion is detected and then, after a selectable period of time, automati-

TEST

Put the ON-TIME switch on the bottom

ON-TIME

of the sensor in the TEST position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5, or

ON-TIME

10 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MANUAL MODE

 

 

 

 

 

 

 

cally turns the lighting off. The built-in photocell keeps the lighting off during daylight hours.

This package includes:

Cover Plate

Gasket

Cover

 

 

 

4 Screws

Plate

(2 sizes)

 

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

 

Halogen

 

 

Bulb

 

 

Sensor

 

 

 

3 Wire

Light Control

Long Bolt

Connectors

Requirements

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch – not a dimmer or other electronic switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at Home Centers and Electrical Supply Stores.

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

 

x

Manual

Until Dawn*

 

x

* resets to Auto Mode at dawn.

Mode Switching Summary

 

TEST

 

 

 

Move ON-TIME Switch

 

 

 

 

 

 

 

 

 

 

 

 

to 1, 5, or 10 minutes

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip switch off for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

one second then
MANUAL MODE

 

 

 

back on*

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time (1 1/2 min.) the control will be in the AUTO mode.

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

Attach the lamp arm to the backplate arm and secure with the long bolt.

Note: When tightening the arm screw, pull on the wires to make sure the wires are not pinched by the joint.

© 2007 HeathCo LLC

595-5496-07

Page 1
Image 1
Heath Zenith manual Motion Sensor Quartz Security Light, Operation, Installation, Model SL-5309, On-Time, Test, Auto