TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

ON-TIME ❒Turn on the circuit breaker and light switch. SENS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

MIN

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of Sensor

Avoid aiming the control at:

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor to aim.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.

Set SENSITIVITY as needed. Too much sensitivity may in- crease false triggering.

Secure the sensor head into position by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME the lights stay on after motion is detected. It is selectable from 1, 5, or 10 minutes.

Clamp

ON-TIME  SENS Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

 

110°

8 ft.

 

(2.4 m)

 

 

60 ft.

 

(18.3 m)

Maximum

Maximum

Range

Coverage Angle

The control is most sensitive to motion across it.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

SPECIFICATIONS

Range

Up to 60 ft.(18.3 m);[varies with

 

surrounding temperature]

Sensing Angle. . . .

Up to 110°

Electrical Load. . . .

Up to 300 Watts Maximum

 

Tungsten

Power Requirements. . 120 VAC, 60 Hz

Operating Modes. . .

TEST, AUTO and MANUAL

 

MODE

Time Delay

1, 5 or 10 minutes

Sensitivity . . . . . . Adjustable

Replacement lamp. . . T 300W (or less) halogen 120

VAC