Heath Zenith SL-5309 Test And Adjustment, Specifications, Bottom of Sensor, Range, Coverage Angle

Models: SL-5309

1 12
Download 12 pages 24.37 Kb
Page 3
Image 3
TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

SENS

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Loosen the clamp screw in the sensor ball joint and gen- tly rotate the sensor to aim.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.

SetSENSITIVITYasneeded. Too much sensitivity may in- crease false triggering.

Secure the sensor head into position by tighten- ing the clamp screw. Do not overtighten the screw.

Set the amount of TIME the lights stay on after motion is detected.Itisselectablefrom 1, 5, or 10 minutes.

Clamp

Screw

Ball

Joint

Aim Sensor Down for Short Coverage

Aim Sensor

Higher for Long

Coverage

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

 

110°

8 ft.

 

(2.4 m)

 

 

60 ft.

 

(18.3 m)

Maximum

Maximum

Range

Coverage Angle

The control is most sensitive to motion across it.

MotionMotion

SENS Sensor

Least Sensitive

Most Sensitive

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 60 ft. (18.3 m); [varies with surrounding temperature]

Sensing Angle . . . . . . . Up to 110°

Electrical Load . . . . . . . Up to 300 Watts Maximum Tungsten

Power Requirements . . 120 VAC, 60 Hz

Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5 or 10 minutes Sensitivity . . . . . . . . . . Adjustable

Replacement lamp . . . T 300W (or less) halogen 120

VAC

DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

595-5496-06