Heath Zenith SL-5330 Test And Adjustment, Specifications, Bottom of Sensor, MotionMotion, Maximum

Models: SL-5330

1 4
Download 4 pages 7.22 Kb
Page 3
Image 3
TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute calibration period before it will detect motion.When first turned on wait 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

MAX

B

ON - TIME

 

 

O

 

O

 

 

S

 

MIN

T

 

 

 

TEST 1 5 2 0

RANGE MINUTES

Bottom of Sensor

Loosen the clamp screw in the sensor ball joint and gen- tly rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cov- eragearea.Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed.RANGE set too high may increase false triggering.

Secure the sensor head's aim by tightening the clamp screw. Do not over- tighten the screw.

Clamp

Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

 

 

240°

8 ft.

 

 

(2.4 m)

 

 

70 ft.

100 ft.

 

(21 m)

(30.5 m)

 

 

Boosted

 

Maximum Range
Maximum

 

 

Coverage Angle

The detector is less sensitive to motion directly towards it.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5 or 20 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature]

Sensing Angle . . . . . . Up to 240°

Electrical Load . . . . . . Up to 300 W Max. Incandescent [Up to 150 W Max. each lamp holder].

Power Requirements . 120 VAC, 60 Hz

Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1 , 5, 20 minutes

DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

MotionMotion

Least Sensitive

Sensor

Most Sensitive

598-1131-01