Heath Zenith SL-5502 installation instructions No Service Parts Available for this Product

Models: SL-5502

1 4
Download 4 pages 26.77 Kb
Page 1
Image 1
Model SL-5502

Model SL-5502

Compact Twin 150 Watt Halogen

The Heath®/Zenith Compact Twin Halogen disperses light over a wide area. It includes two 150W halogen lamps, mounting plate for standard junction box and is for use with 120VAC.

FOR PROPER INSTALLATION AND OPERATION, PLEASE READ THESE INSTRUCTIONS CAREFULLY.

To Avoid Fire or Burn Hazards:

Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.

Keep fixture at least 2" (51 mm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).

Use up to 150 watt lamp maximum per lampholder.

Fixture Installation Instructions

To avoid Electrical Shock:

Compact Twin 150 Watt Halogen WARNING: Turn power off at the circuit breaker or fuse.

Grounding and installations must comply with local codes and the National Electric Code (Canadian Electrical Code).

This product should be mounted on a grounded junction box and must be used with a threaded cover plate.

Permanently mount the fixture to a building or pole. This fixture is for outdoor use and is wall and eave mountable.

Connect all white wires together

Junction box ground

To Avoid Fire or Burn Hazards:Fixture Installation Instructions wire to green ground

screw on fi xture

 

Connect all black

Cover Plate

wires together

Wiring Fixture

Connect the lamp wires to the power source wiring. Secure with wire connectors.

Attach the cover plate to the junction

box (Apply silicon caulk between To avoid Electrical Shock: +/- 4° cover plate and junction box for a rain-

tight seal). Keep the fixture horizontal

(within +/- 4°) so the bulb inside is horizontal. If the bulb is not horizontal, the bulb may darken or shatter and fail prematurely.

Loosen the side bolt connected to the arm to aim the fixture up and down.

For a rain tight seal, caulk the aiming arm joint with silicon caulking compound.

Bulb Installation and Relamping

Important: Use a clean glove or cloth when handling the new bulb. Oil from your hand may cause the bulb to crack when the fixture heats up and result in premature failure. Use isopropyl (rubbing) alcohol to clean the bulb if it is touched with your bare hands.

When relamping, turn power off and let the fixture cool.

Open glass cover and remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.

To insert the new bulb push the bulb into the right socket so the bulb is properly seated in the sockets.

Re-install the glass cover.

Reconnect the power.