Image 2
Mode Switching Summary

Mode Switching Summary

 

TEST

 

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1, 5, or 20 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.

DualBrite® Timer

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.

INSTALLATION

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.

CAUTION: Keep the sensor at least 1" (2.5 cm) away from the lamps.

CAUTION: To Avoid Fire Or Burn Hazards:

Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.

Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).

Use only T3, 150W (max.) tungsten halogen 120 VAC lamps.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing from the light shield and stick on as shown below.

For eave mount only:

Swing the sensor head towards the clamp screw joint.

Controls

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Light Shield

Controls

Opening

 

TEST Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.