TEST AND ADJUSTMENT
Aim Sensor
Higher for Long
Coverage
Clamp Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.

Turn the RANGE control to the mid position, Dual Brite™ to OFF and the ON-TIME control to the TEST position.

MAX

 

 

 

 

B

O

ON - TIME

DUAL BRITE

 

 

O

 

 

 

T

S

 

 

MIN

 

 

 

 

TEST 1 5 2 0

OFF 3 6

DUSK TO

RANGE

 

 

MINUTES

HOUR

DAWN

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as

 

heating vents and air conditioners. These heat

 

sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Loosen the clamp screw in the sensor ball joint and gently ro- tate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.

Keep the sensor at least 2" (51 mm) away from the lamps.

Adjust the RANGE as needed. Too much range may increase false triggering. Range Boost increases coverage up to 100 feet.

Secure the sensor head's aim

by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).

Set the DUAL BRITE™ switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

SPECIFICATIONS

Nearby large, light-colored objects reflecting light

may trigger the shut-off feature. Do not point other

lights at the sensor.

240°

8 ft.

(2.4 m) ❒Turn on the circuit breaker and light switch.

70 ft.

100 ft.

(21 m)

(30.5 m)

 

Boosted

Maximum

Maximum

Range

Coverage Angle

Range . . . . . . . . . . . . . .

Sensing Angle . . . . . . . .

Electrical Load . . . . . . . .

Power Requirements . . .

Operating Modes . . . . . .

Time Delay . . . . . . . . . .

Dual Brite™ Timer . . . . .

Replacement lamp . . . .

Up to 70 ft. (21 m); 100 ft.(30.5 m) with Range Boost. [varies with surrounding temperature]

Up to 240°

Up to 200 Watts Maximum Incandescent (Up to 100 Watts Maximum each lamp holder.)

120 VAC, 60 Hz

TEST, AUTO and MANUAL MODE

1 , 5, 20 minutes

3, 6 hours, Dusk-to-Dawn T4 100W, G8 halogen bi-pin 120 VAC

The control is most sensitive to motion across it.

MotionMotion

Sensor

Least Sensitive

Most Sensitive

DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

598-1038-03

3

Page 3
Image 3
Heath Zenith SL-5597 Test And Adjustment, Specifications, Bottom of Sensor, Range, Coverage Angle, MotionMotion, Maximum