Citizen Systems iDP-460 user manual Serial Interface, Specifications

Models: iDP-460

1 78
Download 78 pages 52.66 Kb
Page 34
Image 34

iDP-460 User’s Manual

7. SERIAL INTERFACE

7.1Specifications

(1)Synchronous system: Asynchronous

(2)Baud rate: 150, 300, 600, 1,200, 2,400, 4,800, 9,600, or 19,200 bps (User selectable)

(3)Configuration of one word

•Start bit

: 1 bit

•Data bits

: 7 or 8 bits (User selectable)

•Parity bit

: Odd, even, or none (User selectable)

•Stop bit

: 1 bit or more

(4)Signal polarity RS-232C

•Mark

=

Logic "1"

(-3 V to -12 V)

•Space

=

Logic "0"

(+3 V to +12 V)

(5)Received data (RD signal) RS-232C

Mark = 1

Space = 0

(6)Reception control (DTR signal) RS-232C

•Mark

: Data transfer disabled

•Space

: Data transfer enabled

(7)Transmission control (TD signal) •Status transmission

P-250

=

Transmits "A"(41h)

P-900R

=

Transmits "H"(48h)

•Printer state transmission

Transmits the data indicating the 1-byte state. (See 10. PRINT CONTROL FUNCTIONS)

34

CITIZEN

Page 34
Image 34
Citizen Systems iDP-460 user manual Serial Interface, Specifications