iDP-460 User’s Manual

BELL (D-type Only)

ALL

[Name]

Drawer kickout

 

[Code]

<07>H

 

[Function]

This command outputs a designation signal to the connected drawer interface.

 

The signal is about 200 ms. Designation is made when the solenoid is

 

connected. The command functions even if not connected to the drawer

 

interface, but it is meaningless.

 

[Caution]

Connect only what is specified to the drawer interface.

Otherwise, when this

 

function is activated, the main body or mating connection element may have a

 

trouble or be destroyed. While this command is functioning, the printer is

 

stopping. Do not specify this command continuously. It could cause a

 

trouble.

 

ESC a (n) ;

ALL

[Name]

Set Line Height

[Code]

<1B>H<61H>(n)<3B>H

[Domain]

7 (n) 255 (<30>H n <39>H)

[Function]

This command defines a height of each print line. A dot line is 1/18 inch. It

 

sets a line feed rate to (n-1)/3/18 inch.

 

A parameter(n) is 7 to 255. If this value is 10, there will be 6 lines per inch.

 

A minimum value of 7 assumes about 9 lines per inch, allowing no space

 

between each line. The line is fed in the set condition until re-setting or

 

initialization(ESC c) is made. The initial condition is restored with "ESC a

 

10; 1" or an initialization command.

[Caution]

Be sure to add ";"(<3B>H) to the end of the parameter.

[Initial Value]

A line height for normal characters is 1/6 inch.[(n) = 10]