10.2Command Sets

A command set is set by a specific command. The available commands and functions differ depending on each setting.

(1)P-250 command set

There are two kinds of modes; P-200 mode and P-250 mode. The P-900R mode are available with a P-900R mode and P-250 mode command. The SI, SO, RS, US, and DC2 command operate differently between the P-200 mode and P-250 mode.

In the P-200 mode, if the 40th character in the line is received, the contents of the buffer will be printed automatically. In the P-250 mode, the default delimits at the 42nd character and printing is performed only after the LF command is received.

(2)P-900R command mode

Basically, this mode is the same as the P-250 mode. It can be set by a command. With the serial interface, if a paper end error is detected in this mode, "#" will be output as the TD signal every second until the paper end error is reset.