7.3.3Error Detection
A parity error, framing error, and overrun error are detected. When an error is detected, that data is either stored in the buffer as "?" or discarded. (Depends on DIP switch selection) The ERROR lamp is illuminated.
(1)Framing error
This error results when a space is detected in detecting the stop bit. That data is either stored in the buffer as "?" or discarded. (Depends on DIP switch selection)
(2)Parity error
If a parity check has been specified and an error is detected at the time of parity check, that data is either stored in the buffer as "?" or discarded. (Depends on DIP switch selection)
(3)Overrun error
If an overrun error is detected, that data is either stored in the buffer as "?" or discarded. (Depends on DIP switch selection)
7.3.4Data Receiving Control
When the DTR signal is a space, the data from the host side can be received. When it is a mark, however, the data cannot be received.
7.3.5Buffering
The DTR signal is available as a control signal for data transfer to the input buffer. •Normal print setting
Capable of buffering