Receiver Information

All receivers have the following features and ratings:

Rated for 120VAC/60Hz supply voltage.

Not for use with Compact Fluorescent bulbs.

When first turned on wait 15 seconds.

Floodlight

Features and Ratings:

• Up to 150 Watt maximum incandescent load or 240 Watt maximum halogen load (up to 75 Watt maximum incandescent,

or 120 Watt maximum halogen, per lampholder).

Minimal wiring required.

Install fixture in accordance with local codes.

WARNING: Turn power off at the fuse or circuit breaker.

1.Remove the existing light fixture.

2.Install the mounting strap as shown using two screws that fit your junction box.

Note: The plastic hanger can be used to hold the fixture while wiring. Thread the small end of the plastic hanger through the hole in the center of the cover plate. Insert the small end into one of the slots on the mounting strap.

3.Route the wires from the light receiver through the large gasket holes.

4.Twist the junction box wires and fixture wires together as shown.

Secure with UL approved wire connectors.

5.Align the cover plate and cover plate gasket. Secure with mounting bolt.

6.Push the rubber plug firmly into place.

7.Not intended for waterproof junction boxes. Fixture should be surface mount only. Caulk the wall plate mounting surface with silicone weather sealant.

8.

Adjust the lamp holders by loosening the lock nuts. Note: Do

 

 

not rotate the lamp holders more than 180° from the factory

 

 

setting.

 

 

 

 

 

 

 

 

Caution: To avoid water damage and electrical shock,

 

 

keep lamp holders 30° below horizontal.

 

 

 

9.

Screw incandescent bulb up to rated wattage into module.

ENGLISH

 

When screwing in the lamps, do not overtighten.

 

 

 

Caution: Do not exceed the maximum load limits listed

 

 

above.

 

 

 

 

 

 

 

10.

Check operation. Activate transmitter being used with receiver

 

 

(see transmitter instructions).Asignal will be sent to the receiver

 

 

to turn the receiver ON or OFF.

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: Risk of fire. Do not aim the lamps at a

 

 

combustible surface within 3 ft. (1 m).

 

 

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

 

 

 

 

White to

 

Black to

 

Rubber

 

 

Strap

 

 

 

 

White

 

Black

 

 

 

 

 

 

Plug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gasket Mounting

Bolt

Junction box ground wire to green

ground screw on fixture.

Wiring Floodlight

598-1296-02

Page 5
Image 5
Heath Zenith UT6028-WH, UT-6028-BZ operating instructions Receiver Information, Wiring Floodlight