Heath Zenith UT-9260-BZ, UT-9260-WH manual Controlling Non-MotionSensing Fixtures

Models: UT-9260-WH

1 42
Download 42 pages 42.67 Kb
Page 7
Image 7
Controlling Non-Motion Sensing Fixtures

Controlling Non-Motion Sensing Fixtures

When wiring to additional standard fixture only: Strip the motion sensor's red wire and connect to the standard fixture's black wire. Connect all white wires together. Total fixture ratings must not exceed 1000 Watts (8.3 A).

NOTE: All wiring between fixtures should be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means.

Contact a qualified electrician if there is any question as to the suitability of the system.

This fixture is provided with a sensor rated for 1000 Watts. Since the fixture is only rated 500 Watts, 500 Watts of additional load may be controlled by this sensor.

When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which speci- fies the maximum lamp wattage for which the fixture is suitable.

Once you have selected the fixtures to be con- nected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325 Watts.

WHITE from Line

to WHITE from Security Light

BLACK from Switch to

RED from Security Light to

BLACK from Security Light

BLACK from Fixture

 

 

Standard

 

Fixture

WHITE from Line to

WHITE from Fixture

Wiring to a Motion Light & Standard Fixture

598-1291-02

--

Page 7
Image 7
Heath Zenith UT-9260-BZ, UT-9260-WH Controlling Non-MotionSensing Fixtures, Wiring to a Motion Light & Standard Fixture