Mount Fixture with Crossbar

Mount Fixture with Crossbar

Mounting Bracket

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture (if appli- cable).

Install the mounting bracket as shown using two screws supplied in hardware pack that fit your junction box:

Rectangular Junction Box - Use two #6-32 x 3/4" screws.

Circular or Octagonal Junction Box - Use

two #8-32 x 3/8" screws.

Watertight Junction Box - Use two #10-24

x 1/2" screws.

The plastic hanger can be used to hold the fix- ture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting bracket.

Route the Light Control’s wires through the large gasket holes.

Standard Wiring

CAUTION: If you have not already turned the power off at the breaker or fuse, do so now.

Connect the junction box wires to the fixture wires. Twist together and secure with wire connectors.

CAUTION: If you are not controlling additional fixtures from your security light fixture, DO NOT connect the RED wire or remove wire connector.

Junction Box

Mounting

Bracket

Green ground

 

wire to junc-

White to

tion box

White

ground wire

 

RED, not

Black to

used in most

Black

applications

 

Gasket

- -

598-1291-02