Brother rh-918a manual List Of Error Codes, Danger

Models: rh-918a

1 89
Download 89 pages 25.39 Kb
Page 84
Image 84
12. LIST OF ERROR CODES

12. LIST OF ERROR CODES

12. LIST OF ERROR CODES

Manual background DANGER

Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the face plate of the control box. Touching areas where high voltages are present can result in severe injury.

When an error occurs, the warning indicator and the error code display flash and the buzzer sounds.

Errors after power is turned on

Code

Explanation

 

Resetting method

 

 

 

 

E-00

EMERGENCY STOP switch was pressed.

1.

Release the EMERGENCY STOP switch.

2.

If an error still occurs after 1. is carried out, check that connector

 

 

 

P3 on the control circuit board is properly connected.

 

 

1.

Turn off the power.

E-02

Machine head is tilted back.

2.

Return the machine head to its original position.

3.

If an error still occurs after 1. is carried out, check that connector

 

 

 

 

 

P8 on the control circuit board is properly connected.

E-03

Cloth presser switch was pressed.

1.

Release the cloth presser switch.

2.

If an error still occurs after 1. is carried out, check that connector

 

 

 

P19 on the control circuit board is properly connected.

E-04

Start switch was pressed.

1.

Release the start switch.

2.

If an error still occurs after 1. is carried out, check that connector

 

 

 

P19 on the control circuit board is properly connected.

 

 

1.

Turn off the power.

E-05

Air pressure is insufficient.

2.

Check the air pressure.

3.

Check that connector P1 on the control circuit board is properly

 

 

 

 

 

connected.

 

 

1.

Move the cloth feed bar to the left so that the feed plate home

E-06

Feed plate home position sensor is OFF.

 

position sensor turns ON.

2.

If an error still occurs after 1. is carried out, check that connector

 

 

 

 

 

P9 on the control circuit board is properly connected.

E-07

Feed plate left range sensor is OFF.

Turn off the power and check that connector P9 on the control

circuit board is properly connected.

 

 

 

 

1.

Turn off the power.

E-09

Specification that machine does not support

2.

Check the specification harness and PROM.

is set.

3.

Check that connector P26 on the control circuit board is properly

 

 

 

 

connected.

 

 

1.

Turn the pulley by hand to raise the needle bar to its highest

E-10

Needle bar is not at the highest position.

 

position.

2.

If an error still occurs after 1. is carried out, check that connector

 

 

 

 

 

P2 on the control circuit board is properly connected.

E-12

Cutter sensor is ON.

Turn off the power and check that connector P3 on the control

circuit board is properly connected.

 

 

E-15

Lower thread trimming OFF sensor is OFF.

Turn off the power and check that connector P8 on the control

circuit board is properly connected.

 

 

 

 

1.

Turn off the power.

E-26

PER terminal connection error

2.

Check that connector P20 on the control circuit board is properly

 

connected.

 

 

3.

Check that connector P2 on the power supply circuit board is

 

 

 

properly connected.

E-27

External RAM error

Turn off the power.

 

 

 

 

 

 

1.

Turn off the power.

E-28

Panel communication start error

2.

Check that connector P18 on the control circuit board is properly

 

connected.

 

 

3.

Check that connector P1 on the panel circuit board is properly

 

 

 

connected.

E-29

Machine motor communication start error

Turn off the power.

 

 

 

 

77

RH-981A

Page 84
Image 84
Brother rh-918a manual List Of Error Codes, Danger