9. STANDARD ADJUSTMENTS
9-23. Adjusting the indexer hole spacing (-52 specifications)
Before carrying out this adjustment, check that the home position adjustment for the cloth feed bar has been carried out correctly. (Refer to page 69.)
Standard
Home position hole
Large size
Home position hole
3112Q | 3113Q |
1.Loosen the bolt (1).
2.Push the cloth feed bar (2) against the bolt (3).
3.Move the feed movable block (4) so that the pin (5) goes smoothly into the indexer holes (38.1 mm - (A), 44.45 mm - (B), 50.8 mm - (C), 57.15 mm - (D)).
4.Place the stopper block (6) firmly against the feed movable block (4), and then tighten the bolt (1) to secure it in place.
Using the set screw collar
Using the set screw collar makes it easy to change between two different hole spacing settings. The
3114Q
<38.1 mm> | <44.45 mm> | |
|
|
|
3115Q
Example: For spacing of 38.1 mm
mm
1.set the hole spacing to 38.1 mm
2.Place the
3.Set the hole spacing to 44.45 mm
4.Place the
5.From now on, if you want to have hole intervals of
38.1mm
Use the same setting method if using other combinations of different hole intervals.
70