9-6. Adjusting the needle guard

9. STANDARD ADJUSTMENTS

9-6. Adjusting the needle guard

Be sure to carry out this adjustment after changing the size of the needle.

The needle must remain stationary with respect to the needle guard until the tip of the looper reaches the needle.

Loosen the screw (1) and then move the needle guard

(3) in the directions indicated by the arrows by an appropriate amount in accordance with the thickness of the needle (2).

Note: Adjust so that the looper clasps the upper thread securely.

3085Q

9-7. Adjusting the spreader mounting positions

3086Q

1.Loosen the screw (3) and adjust the position of the left spreader stopper (4) so that the fork of the left spreader (1) is aligned with the lower thread guide hole of the eye looper (2).

2.Loosen the screw (7) and adjust the position of the right spreader stopper (8) so that the tip of the right spreader

(5)is aligned with the tip of the right looper (6).

Note: Both the left spreader (1) and right spreader (5) should be installed so that they do not project past the tips of the eye looper (2) and right looper (6) respectively.