4. LUBRICATION
Oiling the looper, spreader and looper base
<Removing the work clamp plates>
3031Q
3030Q | 3032Q |
1.Turn the upper shaft pulley (1) toward you until the mark on the pulley (A) is aligned with the notch in the pulley cover (2).
2.Move the feed bracket (3) toward you.
3.Turn the left and right plate pressers (4) in the directions indicated by the arrows.
4.Lift up the clamp lever (6) and the notched section (7) of the right work clamp plate (5), remove the right work clamp plate (5) from the pin (8), and then pull the right work clamp plate (5) toward you to remove it.
Note: If the lower thread trimmer has been installed, move presser plate U (9) to a position where it can be removed without its touching the needle.
Raise presser plate U (9), pass the needle through the hole, and then remove presser plate U (9) from the pin (8).
5.Remove the left work clamp plate (10) in the same way as the right work clamp plate (5) was removed.
3035Q
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3033Q |
| 3034Q |
|
|
| ||
0865Q |
6.Open the front cover.
7.Turn the looper base and add a few drops of oil to the spreader driving cam (11), and to the supports for the looper link (12) and spreader link (13).
8.Add a few drops of oil to the shafts of the right spreader (14), left spreader (15) and
9.Fill the felt tank (17) on the looper base with oil also.
10.Add 5 - 6 drops of oil to the felt (18) which is attached to the sliding surfaces of the looper base and the bed.
11.Close the front cover.
12.Install the work clamp plates by carrying out the steps 5., 4. and 3. in that order.
26