Symptom-to-FRU error messages

Verify that all attached devices are supported computer.

Verify that the power supply being used at the failure is operating correctly. (See “Power syste checkout” on page 9):

1.Power off the computer.

2.Visually check the attached devices damage. problems are found, replace the FRU.

3. Remove or disconnect all of the following devi

a.Non-IBM devices

b.Devices attached to the port replicator

c.Printer, mouse, and other external devices

d.Battery pack

e. Hard disk drive

f. External diskette drive g. DIMM

h. CD-ROM and diskette drive in the UltraslimB

i.PC Cards

4.Power on the computer.

5.

Determine

whether

the

problem

has

changed.

6.

If the problem does not recur, reconnect th

 

devices

one at

a

time

until

you

find

the fa

7.

If

the

 

problem

remains, replace

the

following

 

one

at

a

time.

Do

not

replace a

nondefective

a.System board

b.LCD assembly

c.CPU card

32 ThinkPad 600X Hardware Maintenance Manual

Page 36
Image 36
IBM 600X (MT 2646) manual Symptom-to-FRU error messages