12. LIST OF ERROR CODES
Errors during operation
Code |
|
|
| Explanation |
|
|
|
|
| Resetting method | |||
|
|
| |||||||||||
Needle down sensor is not activated within a | Turn off the power and check that connector P2 on the control | ||||||||||||
specified time. |
|
|
|
|
|
|
| circuit board is properly connected. | |||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| 1. Turn off the power. | ||
Cutter | sensor | is | not | activated | within | a | 2. | Check that air is reaching the valve. | |||||
specified time. |
|
|
|
|
|
|
| 3. | Check that connectors P3 and P4 on the control circuit board | ||||
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| are properly connected. | |
|
|
|
|
|
|
|
|
|
|
| 1. Turn off the power. | ||
Lower | thread | trimming | OFF sensor | is | not | 2. | Check that air is reaching the valve. | ||||||
activated within a specified time. |
|
|
| 3. | Check that connector P8 on the control circuit board is properly | ||||||||
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| connected. | |
Needle up sensor is OFF during test feeding. | Turn off the power and turn the pulley by hand to raise the needle | ||||||||||||
bar to its highest position. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Synch | signal | is | not | activated | within | a | Turn off the power and check that connector P2 on the control | ||||||
specified time. |
|
|
|
|
|
|
| circuit board is properly connected. | |||||
|
|
|
|
|
|
|
| ||||||
| X home | position | sensor is | not | set | to ON | Turn off the power and check that connector P7 on the control | ||||||
within | a | specified | time | of | searching | home | |||||||
circuit board is properly connected. | |||||||||||||
| position. |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| |||||||||
Y home position sensor is not set to ON |
| Turn off the power and check that connector P6 on the control | |||||||||||
within a specified time of searching home |
| ||||||||||||
| circuit board is properly connected. | ||||||||||||
| position. |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| 1. Turn off the power. | ||
| θ home position sensor is not set to ON | 2. Check that connectors P11 and P13 on the control circuit board | |||||||||||
within a specified time of searching home |
| are properly connected. | |||||||||||
| position. |
|
|
|
|
|
|
|
| 3. Check that connectors P1, P2 and P3 on the θ axis PMD circuit | |||
|
|
|
|
|
|
|
|
|
|
|
| board are properly connected. | |
Machine motor reverse operation error |
|
| Turn off the power and check that the motor cord is properly | ||||||||||
|
| connected. | |||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| Hardware errors | |||
|
|
|
|
|
|
|
|
|
|
| |||
Code |
|
|
| Explanation |
|
|
|
|
| Resetting method | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| 1. Turn off the power. | ||
| Communication error (against machine motor | 2. Check that connector P18 on the control circuit board is properly | |||||||||||
| connected. | ||||||||||||
CPU) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 3. Check that connector P1 on the panel circuit board is properly | |||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| connected. | |
|
|
|
|
|
|
|
|
|
|
|
| ||
Machine motor running error |
|
|
|
| Turn off the power and check that connector P2 on the control | ||||||||
|
|
|
| circuit board is properly connected. | |||||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| 1. Turn off the power. | ||
Abnormal voltage error |
|
|
|
|
| 2. Check that the power supply voltage matches the rated voltage. | |||||||
|
|
|
|
| 3. Check that connector P20 on the control circuit board is properly | ||||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| connected. | |
Fan (large) lock error |
|
|
|
|
| Turn off the power and check that connector P10 on the control | |||||||
|
|
|
|
| circuit board is properly connected. | ||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Fan (small) lock error |
|
|
|
|
| Turn off the power and check that connector P25 on the control | |||||||
|
|
|
|
| circuit board is properly connected. | ||||||||
|
|
|
|
|
|
|
|
|
|
| |||
X motor overcurrent error |
|
|
|
| Turn off the power and check that connector P7 on the control | ||||||||
|
|
|
| circuit board is properly connected. | |||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Y motor overcurrent error |
|
|
|
| Turn off the power and check that connector P6 on the control | ||||||||
|
|
|
| circuit board is properly connected. | |||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Control circuit board temperature rise error | Turn off the power and check that the inside of the control box is | ||||||||||||
being properly ventilated. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Power supply relay error |
|
|
|
|
| Turn off the power and check that connector P20 on the control | |||||||
|
|
|
|
| circuit board is properly connected. | ||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Power supply circuit board overcurrent error | Turn off the power and check that connectors P12 and P13 on the | ||||||||||||
control circuit board are properly connected. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
79