C. LOCATION AND CLEARANCES

BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS

C. LOCATION AND CLEARANCES

Dimensions

WARNING!

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

1.APPLIANCE LOCATIONS AND SPACE REQUIREMENTS

Figure 1 illustrates a variety of ways the appliance may be located in a room. The Builder's Choice Series may be installed directly on the floor or on a hearth. These appliances are certified for installation in a bedroom, bed/sitting room or in mobile homes in the U.S. and Canada.

2. CLEARANCES

a. For the appliance:

 

Top of standoffs

0”

Floor

0”

Back of appliance

1/2”

Sides

1/2”

Front Face to Ceiling

30”

b.Minimum Venting Clearances (see Figure 2).

1)Horizontal runs off of the back of the appliance to the wall shield:

0” above the top of the appliance standoffs 1” sides and bottom of the vent

2)Horizontal runs inside a wall (heat shields must be installed)

3” air space on top of the vent 1” from sides and bottom of vent

3)Vertical runs

1” air space around the vent

Note: Dimensions represent minimum space required for a centered corner installation. Actual requirements will vary with individual construction.